Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Mol Sci ; 23(14)2022 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-35887368

RESUMO

In this work, we developed and validated a robust and sensitive method of liquid chromatography with high-resolution mass spectrometry in parallel reaction monitoring (PRM) mode for ST-246 (tecovirimat) quantification in human blood plasma. The method was compared with the multiple reaction monitoring (MRM) technique and showed better selectivity and similar sensitivity in a wider concentration range (10-5000 ng/mL). Within this range, intra- and interday variability of precision and accuracy were within acceptable ranges in accordance with the European Medicines Agency guidelines, and recovery was 87.9-100.6%. Samples were stable at 4 °C within 48 h and at -20 °C up to 3 months. The recovery and matrix effects in the proposed HRMS method were about 5% higher than those reported for the MRM method, but the PRM method showed better accuracy with comparable precision. It was found that the ST-246 concentration shown by the PRM method is approximately 24% higher than the output of the MRM one. Nonetheless, the high selectivity with similar sensitivity, as compared with traditional MRM methods, makes the proposed approach attractive for research and clinical use.


Assuntos
Benzamidas , Bioensaio , Isoindóis , Benzamidas/sangue , Cromatografia Líquida , Humanos , Isoindóis/sangue , Espectrometria de Massas , Plasma , Reprodutibilidade dos Testes
2.
Molecules ; 27(11)2022 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-35684513

RESUMO

The aim of this work was to develop and validate a sensitive and robust method of liquid chromatography coupled with tandem mass spectrometry to quantitate ST-246 (tecovirimat) in plasma using an internal standard (2-hydroxy-N-{3,5-dioxo-4-azatetracyclo [5.3.2.02.6.08.10]dodec-11-en-4-yl}-5-methylbenzamide). The method was validated in negative multiple reaction monitoring mode following recommendations of the European Medicines Agency for the validation of bioanalytical methods. The calibration curve for the analyte was linear in the 10−2500 ng/mL range with determination coefficient R2 > 0.99. Intra- and inter-day accuracy and precision for three concentrations of quality control were <15%. Testing of long-term stability of ST-246 (tecovirimat) in plasma showed no degradation at −20 °C for at least 3 months. The method was applied to a clinical assay of a new antipoxvirus compound, NIOCH-14. Thus, the proposed method is suitable for therapeutic drug monitoring of ST-246 (tecovirimat) itself and of NIOCH-14 as its metabolic precursor.


Assuntos
Plasma , Espectrometria de Massas em Tandem , Benzamidas , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida , Humanos , Isoindóis , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...